HOW TO GET HELP 2
GENERAL DESCRIPTION
OF THE UNIVERSAL ANAESTHESIA MACHINE®2
DEFINITION OF STATEMENTS 2
SPECIFICATIONS3-4
COMPONENTS OF THE UAM®5-9
CHECKLISTS10
Prior To Every Operating Session10
Prior To Every Patient Case11
Following Every Patient Case11
Following Every Operating Session11
USING THE CONTROL SCREEN11
Calibrating The Oxygen Monitor11
Calibrating The Apnoea Alarm Sensor12
Setting The Oxygen Alarms12
Setting The Apnoea Alarm On Or Off12
FILLING THE VAPORIZER13
USING THE UAM13
Balancing Gas Supply And Patient Demand13-14
Using The Bellows15
Using The Oxygen Concentrator15
Using An Attached Oxygen Cylinder16
Using A Pipeline Connector16
Using The Emergency Oxygen Inlet16
Using Nitrous Oxide16
Using An Ayre's T-Piece (ATP)17
Using The UAM To Provide Oxygen For An Awake Patient18
PREVENTATIVE MAINTENANCE19
Cleaning The Halothane Vaporiser19
Replacing The Oxygen Sensor19
Replacing The Oxygen Concentrator Filter20
Cleaning The Breathing Circuit20-22
APPENDIX ONE: BREATHING CIRCUIT DIAGRAM23

Table Caption: This table of contents outlines the key sections and subsections of a manual for the Universal Anaesthesia Machine (UAM), covering its description, components, operation, maintenance, and safety features. It provides a structured guide to understanding and using the UAM effectively.

HOW TO GET HELP

EMAIL:

[email protected]

WEB:

www.gradianhealth.org

PHONE:

+1.212.537.0340

ADDRESS: Gradian Health Systems, 160 Fifth Avenue, 7th Floor, New York, NY 10010, USA

GENERAL DESCRIPTION OF THE UNIVERSAL ANAESTHESIA MACHINE®

The UAM ® combines elements from both continuous flow and draw-over designs to provide a workstation that delivers controlled anaesthesia in all hospital settings. Oxygen can be provided from a variety of sources, and if none of those sources is available the machine will automatically draw in room air without the need for the user to change settings. The vaporizer provides calibrated delivery of anaesthetic agent and the manual bellows ensures that safe assisted respiration can continue without requiring a high pressure gas source.

The system has been designed to accept standard anaesthesia accessories such as the breathing circuit, oxygen sensor, and standard connectors for the oxygen and nitrous oxide supplies. The UAM is also designed for simple field service. Most components can be removed with standard tools and a replacement part installed by local technicians without removing the workstation from the hospital.

The UAM carries the CE Mark, having passed through EU regulatory inspections. It is manufactured in an ISO-certified factory in England. It is used in a wide variety of hospitals, from internationally recognized academic centers to resource-constrained district hospitals.

DEFINITION OF STATEMENTS

The following terminology and statements are important for the operator to understand before consulting the user's manual for the UAM:

WARNING: Indicate a possibility of injury to the operator or others.

CAUTION: Indicate a possibility of